Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 3:28am On Sep 14, 2016
About 23 special cast labourers in their groups, positioned themselves around the building as they are pleased for better performance.

In our usual way we took a gauge of 6" transfer it to another end tie a line or rope as a guide for the masons so they will cast the marked area and make sure is same height. After which they will cast up the partition and it goes on like that.... Follow me

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 3:34am On Sep 14, 2016
....we don't take our gauge from the board for a good result, for a more better slab.

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 4:01am On Sep 14, 2016
And so it is... And must be a good mix as we know that too much water in a concrete weakens its workablity.

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 5:10am On Sep 14, 2016
We are good for the day thank you for following.... We will feed you with more info after 48hours. thanks once again

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by gist4kidsblog: 6:40am On Sep 14, 2016
Call/WhatsApp for your roofing

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 6:03am On Sep 20, 2016
Alright, good day all, after the break-time which lasted a bit longer that I proposed, we have to continue with the 4th stage of the building at once...

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 6:19am On Sep 20, 2016
...

1 Like

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 9:28am On Sep 26, 2016
The owner of this structure have intentions of making it a 12flats Apartment, that is two storey building initially but with the cost of material in the market now he doubt if he will continue with the two storey building plan.

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 9:38am On Sep 26, 2016
But sincerely, days are hard now .... 16mm @ about #3000 each. Well I pray God's provision for our clients in Jesus name!

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by abdulwastecx(m): 4:55am On Feb 09, 2017
dubemcapital:
And so it is... And must be a good mix as we know that too much water in a concrete weakens its workablity.

Too much water in a concrete weakens the concrete and improve the workability. Water enhance the workability of concrete but with the detrimental effect of reducing the strength of the concrete.

Reasons why we do mix design to get the best water to cement ratio to use for work. Generally, a water to cement of 0.45, 0.55 is used. The smaller the water ratio the better the concrete strength but the less workable the concrete becomes

4 Likes

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 5:51am On Feb 22, 2017
abdulwastecx:


Too much water in a concrete weakens the concrete and improve the workability. Water enhance the workability of concrete but with the detrimental effect of reducing the strength of the concrete.

Reasons why we do mix design to get the best water to cement ratio to use for work. Generally, a water to cement of 0.45, 0.55 is used. The smaller the water ratio the better the concrete strength but the less workable the concrete becomes


Definition of Workability

The property of fresh concrete which is indicated by the amount of useful internal work required to fully compact the concrete without bleeding or segregation in the finished product.

These are Factors that affect workability:

Water content in the concrete mix, Amount of cement & its Properties, Aggregate Grading (Size Distribution), Nature of Aggregate Particles (Shape, Surface Texture, Porosity etc.) & Method of placement.

When there is too much water in the concrete, there is greater shrinkage with the possibility for more cracks and reduced compressive strength. As a general rule, every additional inch of slump decreases strength by approximately 500 psi. So for example, if you ordered 5-inch slump concrete and received 7½ inches, a mix designed to be 4000 psi would end up being 2500 psi. This represents a serious loss in strength. statistics has shown that over the years.

Thanks

1 Like

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by fendorf(m): 10:35am On Feb 23, 2017
dubemcapital:
For posterity sake internal beam is advised in a large room Or space when decking is involved. It's spacing too is of a higher importance...

Here we use 16mm for all the beams and internal beams, the entire steel rope (rings) are 8mm, while we used 12mm for the slab mat all through. The step is combination of 16mm and 12mm as well...
plus how many bags of cement did you use for the decking of the first floor?
Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 3:19pm On Feb 24, 2017
fendorf:
plus how many bags of cement did you use for the decking of the first floor?



About 185 bags
Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 3:22pm On Feb 24, 2017
We recently resumed work... Pictures Uploading

1 Like

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 3:34pm On Feb 24, 2017
The slight bent beam formation took place after the scaffold.

2 Likes

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 3:37pm On Feb 24, 2017
Parapet form Work

1 Like

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 8:00pm On Feb 24, 2017
...

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 8:03pm On Feb 24, 2017
Its a unique design, using plank all through.

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 5:01am On Mar 04, 2017
Parapet cast took a while , not like pop type. I decided not do a pop parapet anymore because it takes a longer time and cash intensive too
Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 9:17pm On Mar 05, 2017
Roof wood structure

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 9:23pm On Mar 05, 2017
....

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 9:29pm On Mar 05, 2017
Almost ready for roofing sheets

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 7:13am On Mar 06, 2017
Parapet finishing

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 7:22am On Mar 06, 2017
More pics

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 7:29am On Mar 06, 2017
Roofing, almost through with...

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 4:38am On Mar 10, 2017
Finishing in stages

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 4:41am On Mar 10, 2017
It's electrical installation

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 4:49am On Mar 10, 2017
Making of Saptic Tank and Sock Away

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 5:02am On Mar 10, 2017
Deeper? Yes I need 3300m below the soil surface, then make up about 700 m above the surface

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 5:17am On Mar 10, 2017
Well this the best time to build septic tank in a place like this... So we are going to make a quality concrete blind of 4" (inches) before any other thing.

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 5:23am On Mar 10, 2017
Preparing the pit for cast work. we pray rain doesn't meet us hear.

Re: **the Making Of 2storey Building (12 Flats) Of One Bedroom Apartment In Enugu** by dubemcapital(m): 5:54am On Mar 10, 2017
After the tank final blind cast, the wood work continued.

(1) (2) (3) (4) (5) (6) (7) (8) (Reply)

Places In Lagos You Should Be Careful Of Before Buying Land / Lady House Hunting Shares Photo Of Kitchen In Apartment She Was Asked To Inspect / Landlords In Rivers State Controlling Floods By Digging Trench (Photos)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 27
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.